Abstract:
Taking the reconstruction of four-storey frame structure building (first
floor overhead) in the 7th degree area as an example, the seismic performance
of buildings before and after partial addition of reinforced concrete floor in the
overhead layer was analyzed by using the design and calculation software of
Yingjianke. The main seismic performance of the building structure before and
after the reconstruction were compared, such as the natural vibration period,
lateral displacement, shear to span ratio of column, shear force change of
column top and bottom and vertical irregularity of the structure. The calculation
and analysis show that the seismic performance of the whole structure does not
change much after the reconstruction, but the seismic performance of some
components is weakened. The analysis results are of reference significance to
the safety appraisal, renovation design and reinforcement construction of local
reconstruction engineering of building structures.
以七度区四层框架结构建筑(首层架空)局部加层改造为例,采用盈建科设计计
算软件分析了架空层局部增设钢筋混凝土楼盖前后的房屋抗震性能,对比了改
造前后房屋结构的自振周期、侧向位移、柱剪跨比、柱顶柱底剪力变化以及结
构竖向不规则等主要抗震性能计算结果。计算分析表明,改造后结构整体抗震
性能变化不大,但个别构件抗震性能弱化。分析结果对建筑结构局部改造工程
的安全鉴定改造设计、加固施工具有参考意义。